Search results for "Grid interaction"
showing 4 items of 4 documents
Load match and grid interaction optimization of a net zero energy building through electricity storage: An Italian case-study
2016
The study aims at applying of Load Match and Grid Interaction indexes to a Net Zero Energy Building in order to optimize the performances of its energy systems. The case study is a modular prefabricated house that uses solar energy (photovoltaic) and natural gas (Fuel Cell) as energy sources and equipped with an Energy Management System addressing the optimal energy use.
Grid interaction and environmental impact of a net zero energy building
2020
Abstract The concept of Net Zero Energy Building (NZEB), as a grid-connected building that generates as much energy as it uses over a given period, has been developing through policies and research agendas during the last decade as a contribution towards the decarbonization of the building sector. However, since the most applicable and widely used renewable energy supply options are non-programmable, the large-scale NZEBs diffusion into the existing power grids can seriously affect their stability having a relapse on operation costs and environmental impacts. In this context, the study aims at performing the design of the energy systems to be used in the case-study through a wide numbers of…
Towards an integrated design of renewable electricity generation and storage systems for NZEB use: A parametric analysis
2021
Abstract Although nearly zero energy buildings have attracted growing research attention, literature analysis shows that only a limited number of researches try to couple load match/grid interaction issues and environmental impacts in early design stages. The study proposes a novel multidisciplinary design approach that allows to integrate these two conflicting aspects aiming to find trade-offs. The proposed approach has been applied to a building case study, equipped with a photovoltaics system without energy storage. The results show that even though on yearly basis the energy use (5,290 kWhe) is largely overcome by the on-site energy generation (8069 kWhe), an oversized PV system alone m…
Ventilative cooling application in Mediterranean buildings: impacts on grid interaction and load match
2016
The concept of load matching refers to the simultaneous occurrence of loads and generation in buildings: it can be increased and optimised with modifications on both the energy demand and generation, but its pre-requisite is to guarantee passive energy efficiency. In the Mediterranean areas, a major challenge in new buildings is the increasing overheating even during mildly hot seasons. Ventilative cooling can be a potential solution to such issues and have an impact on load match in buildings and their grid interaction. The study analyses the potential of ventilative cooling to improve the load match in three different case studies in Italy. Ventilative cooling proved viable in moderately …